This exhibit represents a conventional gasoline vehicle with a fixed-displacement compressor, a thermostatic expansion valve, and a coolant heater core. The vehicle installation and internal teaching geometry are reconstructions; this is not a service or manufacturing drawing.
Mechanical reference
Seven-piston compressor reference: seven cylinders, 29.3 mm bore, 32.8 mm stroke, 154.9 cm³ per revolution; 132.2 mm double V-groove pulley and 12 V magnetic clutch. External mount and port features follow the manufacturer drawing. Hidden linkages, clearances, valve reeds, fins and sectioned galleries are adapted for explanation. The anti-rotation restraint is an idealized kinematic representation. A separate reconstructed inline-four crank mechanism now supplies the pulley through a continuous shaft and belt. The 12 V coil engages the clutch; fuel-powered engine shaft work drives compression.
Three independent media
Refrigerant circulates through compressor, condenser, receiver-drier, TXV and evaporator. Coolant circulates through engine and heater core, with thermostat-controlled radiator and bypass branches. Air flows across the outside of the heat exchangers. Particle temperature always uses one blue-to-orange scale. Refrigerant concentration follows calculated density, including its phase; denser liquid has many more particles than vapor. The density range and travel speed are compressed for readability, so tracers are not literal molecules. Surface colors may use realistic materials or a temperature overlay.
Thermodynamics
R134a saturation, superheated-vapor and compression properties are interpolated from embedded thermodynamic property library HEOS tables. The four-state running cycle obeys h₄ = h₃, Q̇e = ṁ(h₁−h₄), Ẇref = ṁ(h₂−h₁), Q̇c = ṁ(h₂−h₃). Shaft input includes modeled mechanical losses. The dynamic model separately balances the evaporator metal, condenser metal, engine, coolant, heater core, cabin air and cabin moisture.
Evaporator heat entering the refrigerant can differ transiently from cabin-air cooling because metal stores heat. With the clutch open, a fading diagram shows the last running cycle; current manifold pressures relax, while detailed off-state phase distribution is unresolved.
Scientific presentations
ChooseScientific tourfor two full-screen, captioned sequences: cooling (2:45) and cold-start heating (2:42). Nineteen chapters connect component mechanisms to actual piping and air passages. Cooling uses 35°C ambient conditions; heating starts at 5°C and uses 10× thermal time to show 27 minutes of warm-up. The engine-coolant heater supplies cabin heat. Temporary transparent sections expose the clutch coil and valve reeds. Caption, chapter, pause and camera-motion controls support inspection. Exiting restores the previous laboratory state.
Process highlighting follows the operating state and selected explanation. Relevant hardware retains its material and temperature display; inactive or background hardware is neutral. Physically circulating background fluids remain faintly visible. The films use 3× particle volume and 82% pipe opacity. Particles retain the shared temperature scale and calculated refrigerant density; display changes do not change the physical solution.
Operating assumptions
- Single well-mixed cabin, representative thermal masses and heat-exchanger conductances; no measured vehicle calibration.
- Sea-level pressure, 101.325 kPa; supported ambient −10 to 42 °C, humidity 10–95%, engine speed 800–3,500 rpm.
- Fixed 1.25 A/C pulley ratio and separate 1:1 coolant-pump belt. Belts use exact tangent paths and derive travel from the same crank/pulley angle. Clutch engagement is idealized; no belt elasticity, slip, combustion or torsional dynamics.
- Quasi-steady refrigerant cycle, lumped transient heat and moisture storage; no CFD, refrigerant-charge inventory, oil circulation, acoustic model or production performance map.
- TXV metering is an effective steady superheat control model; diaphragm geometry and displacement are explanatory. Vapor mass fraction and vapor volume fraction are reported separately. Pipe pressure drops and refrigerant inventory are not solved; each line uses its corresponding cycle pressure. Air is near atmospheric pressure; blower pressure rise and duct/core losses are qualitative because no fan-curve resistance network is fitted. Coolant hydraulic pressure is not solved.
- Thermal time and slowed mechanical playback are independent. Flow-tracer size and speed, reed lift and selected sections are visual aids.
- The expanded teaching layout translates rigid assemblies and extends connecting lines; its spacing is explanatory. Cold-start mode begins at ambient. Normal reset uses an already-warm engine. The opening cooling view is preconditioned for 60 simulated seconds.
Primary sources
The supplied reconstruction uses reference compressor dimensions and service diagrams. Component shapes, piping routes, and cabin thermal masses remain an educational reconstruction, rather than production CAD or a certified vehicle model.
R134a equation of state: Tillner-Roth and Baehr (1994)
Humidity and condensation use standard humid-air correlations at sea-level pressure. Full source provenance and numerical assumptions accompany the exhibit implementation.
Verification
The source package contains reproducible property-table checks, thermal scenario tests, sampled full-cycle kinematic tests, and the implementation validation report. These establish consistency within the stated model, not manufacturer-equivalent performance or continuously proven collision-free solids.